A Literature Review on the Evaluation of Design Parameters for Modern Grease Traps and High Strength Wastes, R. R. Kommalapati, R. Johnson, 2001
http://www.tceq.texas.gov/assets/public/compliance/compliance_support/regulatory/ossf/LitReviewOnTheEval.pdf
Assessment of Grease Interceptor Performance, Water Environment Research Foundation, 2008
http://www.ndwrcdp.org/documents/03-cts-16t/03cts16taweb.pdf
Basic Principles for Sizing Grease Interceptors, Plumbing and Drainage Institute
http://www.pdionline.org/storage/publications/Basic-Principles-for-sizing-Grease-Interceptors.pdf
Brown Grease Supply Study, Kennedy/Jenks Consultants, Commissioned by Clean Water Services (Washington County Oregon), 2011
http://www.schierproducts.com/literature/BGSS_KJ_2011.pdf
Characterization of Grease Interceptors for Removing Fat, Oil and Grease (FOG) and Mechanisms of FOG Deposit Formation in Sewer Systems, X. He, 2012
http://repository.lib.ncsu.edu/ir/bitstream/1840.16/7974/1/etd.pdf
Commercial Food Waste Disposal Study, New York City Department of Environmental Protection, 2008
http://www.nyc.gov/html/dep/pdf/dep_commercial_food_waste_disposal_study_12312008.pdf
http://www.jstor.org/stable/25029790
Design Manual: Onsite Wastewater Treatment and Disposal Systems, US EPA, 1980
http://water.epa.gov/infrastructure/septic/upload/septic_1980_osdm_all.pdf
EPA Report to Congress, US EPA 833-R-04-001, 2004
http://water.epa.gov/polwaste/npdes/cso/2004-Report-to-Congress.cfm
Fact Sheet National Pretreatment Program Controlling Fats, Oils, and Grease Discharges from Food Service Establishments, US EPA 40 CFR 403, 2012
http://www.epa.gov/npdes/pubs/pretreatment_foodservice_fs.pdf
FOG Interceptor Design and Operation (FOGIDO) Guidance Manual, Water Environment Research Foundation, 2008
http://www.ndwrcdp.org/documents/03-cts-16t/03cts16tbweb.pdf
Food-Service Establishment Wastewater Characterization, B. J. Lesikar, O. A. Garza, R. A. Persyn, A. L. Kenimer, M. T. Anderson, 2006
http://ossf.tamu.edu/files/2011/06/food_waste.pdf
Methods of Estimating Loads in Plumbing Systems, Building Materials and Structures Report, BMS65, Roy B. Hunter, 1940
http://fire.nist.gov/bfrlpubs/build40/PDF/b40002.pdf
Onsite Treatment and Disposal of Restaurant Wastewater, R. L. Siegrist, J. C. Converse, D. L. Anderson, 1984
http://www.soils.wisc.edu/sswmp/pubs/10.13.pdf
Onsite Wastwewater Treatment systems Manual, US EPA, 2002 (update to 1980 Design Manual)
http://water.epa.gov/aboutow/owm/upload/2004_07_07_septics_septic_2002_osdm_all.pdf
Orange County Fats, Oils, and Grease (FOG) Control Study, Phase 1, Environmental Engineering and Contracting, J. Shaffer et. al., 2003
Orange County Fats, Oils, and Grease (FOG) Control Study, Phase 2, Final Report, Environmental Engineering and Contracting, J. Shaffer et. al., 2006
Properties Influencing Fat, Oil, and Grease Deposit Formation, K. M. Keener, J. J. Ducoste, L. M. Holt, 2007
https://...ResearchGate
Onsite Wastwewater Treatment systems Manual, US EPA, 2002 (update to 1980 Design Manual)
http://water.epa.gov/aboutow/owm/upload/2004_07_07_septics_septic_2002_osdm_all.pdf
Orange County Fats, Oils, and Grease (FOG) Control Study, Phase 1, Environmental Engineering and Contracting, J. Shaffer et. al., 2003
Orange County Fats, Oils, and Grease (FOG) Control Study, Phase 2, Final Report, Environmental Engineering and Contracting, J. Shaffer et. al., 2006
Properties Influencing Fat, Oil, and Grease Deposit Formation, K. M. Keener, J. J. Ducoste, L. M. Holt, 2007
https://...ResearchGate
Separation of Pollutants from Restaurant Wastewater by Electrocoagulation, X. Chen, G. Chen, P. L. Yue, 1999
Testing and Rating Procedure for Hydro Mechanical Grease Interceptors with Appendix of Sizing and Installation Data, Standard PDI G-101, Plumbing and Drainage Institute, 1996
http://waterky.org/files/pdi-g101.pdf
Testing and Rating Procedure for Hydro Mechanical Grease Interceptors with Appendix of Installation and Maintenance, Standard PDI G-101, Plumbing and Drainage Institute, 2012
http://www.pdionline.org/storage/publications/PDI-G101.pdf
Testing and Rating Procedure for Hydro Mechanical Grease Interceptors with Appendix of Installation and Maintenance, Standard PDI G-101, Plumbing and Drainage Institute, 2015
http://plumbinganddrainage.org/storage/publications/PDI-G101-Revised-April-2015.pdf
Urban Waste Grease Resource Assessment, National Renewable Energy Laboratory, 1998
http://www.nrel.gov/docs/fy99osti/26141.pdf
The University of Iowa Studies in Engineering, Bulletin 30, The Iowa Institute of Hydraulic Research, 1946
Upgrading the Conventional Grease Trap using a Tube Settler, W. Chu, F. Ng, 2000
http://www.deepdyve.com/lp/elsevier/upgrading-the-conventional-grease-trap-using-a-tube-settler-WpKwBjrMwU
Very Nice list of helpful study's and articles.